2 ton - best for spaces between 1000 - 1200 sq ft depending on your home's insulation and your climate
SEER2 rating helps consumers compare energy efficiency when choosing a new air conditioner. Higher SEER2 ratings mean significant utility savings. The federal minimum is 14 SEER2 with ratings into the 20 SEER2 range. A 20 SEER2 uses half the energy of a 10 seer much like MPG ratings for vehicles.
Good for extreme southern climates with very low heating demand such as south Florida and south Texas (otherwise a heat pump is the best option)
If you have an indoor furnace, or air handler, along with an outdoor AC unit, this system will serve as a replacement for both.
Goodman AC & Air Handler | 2 Ton 18.5 SEER2 2 Stage AC With Electric Heat - Horizontal R32 | For Very Mild Winter Climates
AC Size Calculator | Get BTU’s and Tonnage – Free and Easy!
Welcome! START HERE:
Use the sizing calculator below to calculate your required system size.
Follow these easy steps:
Air Conditioning Square Footage Range by Climate Zone
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
1.5 Tons
600 - 900 sf
600 - 950 sf
600 - 1000 sf
700 - 1050 sf
700 - 1100 sf
2 Tons
901 - 1200 sf
951 - 1250 sf
1001 - 1300 sf
1051 - 1350 sf
1101 - 1400 sf
2.5 Tons
1201 - 1500 sf
1251 - 1550 sf
1301 - 1600 sf
1351 - 1600 sf
1401 - 1650 sf
3 Tons
1501 - 1800 sf
1501 - 1850 sf
1601 - 1900 sf
1601 - 2000 sf
1651 - 2100 sf
3.5 Tons
1801 - 2100 sf
1851 - 2150 sf
1901 - 2200 sf
2001 - 2250 sf
2101 - 2300 sf
4 Tons
2101 - 2400 sf
2151 - 2500 sf
2201 - 2600 sf
2251 - 2700 sf
2301 - 2700 sf
5 Tons
2401 - 3000 sf
2501 - 3100 sf
2601 - 3200 sf
2751 - 3300 sf
2701 - 3300 sf
2 ton - best for spaces between 1000 - 1200 sq ft depending on your home's insulation and your climate
SEER2 rating helps consumers compare energy efficiency when choosing a new air conditioner. Higher SEER2 ratings mean significant utility savings. The federal minimum is 14 SEER2 with ratings into the 20 SEER2 range. A 20 SEER2 uses half the energy of a 10 seer much like MPG ratings for vehicles.
Good for extreme southern climates with very low heating demand such as south Florida and south Texas (otherwise a heat pump is the best option)
If you have an indoor furnace, or air handler, along with an outdoor AC unit, this system will serve as a replacement for both.
Commissioning and diagnostics via on board Bluetooth with the CoolCloud™ phone and tablet application
Advanced configuration of the airflow and tonnage in communicating mode
Provides constant CFM over a wide range of static pressure conditions independent of duct system
CFM indicator
Fault recall of six most recent faults
Provides adjustable low CFM for efficient fan-only operation
Improved humidity and comfort control
Built-in compatibility with multi-stage heat pump and cooling applications
UL 60335 2-40 Compliant
AHRI certified; ETL listed
Cabinet Features
Blower section usable as electric heater
Horizontal or vertical configuration capabilities
21” depth for easier attic access
Foil-faced insulation covers the internal casing to reduce cabinet condensation
Galvanized, leather grain-embossed finish
Cabinet air leakage less than 2% at 1.0 inch H20 when tested in accordance with ASHRE standard 193
Cabinet air leakage less than 1.4% at 0.5 inch H20 when tested in accordance with ASHRE standard 193
Field Installed 3 kW – 20 kW electric heater kits available
CHPTA Overview
Standard Features
All-Aluminum evaporator coil
Optimized for use with R-32 refrigerant including circuits and manifolds
R-32 sensor designed for the life span of the coil
CAPTA and CHPTA models feature factoryinstalled thermal expansion valves for cooling and heat pump applications
Standardized copper suction tube stub length
Vertical and horizontal models available
21" depth for easier attic access
CAPTA and CHPTA models include a single front access panel
Foil-faced insulation covers the internal casing to reduce cabinet condensation
Galvanized, leather grain-embossed finish
Rust resistant, thermoplastic drain pans featuring a low water-retention design
DecaBDE-free thermoplastic drain pan with secondary drain connections
Drain pan rails designed to remove and reposition coils with ease without compromising structural integrity
UV-resistant drain pan
AHRI certified; ETL listed
Note: Do not use these coils on oil furnaces or any applications where the temperature on the drain pan may exceed 300° F. If these coils are applied with an oil furnace or another application where high temperatures threaten or jeopardize the durability of the drain pan, you must replace the factory-installed drain pan with a high-temperature drain pan. High-temperature drain pan kits are available as field-installed accessories.
ACDirect does not yet provide installation services directly. However, most of our customers successfully arrange installation through local licensed HVAC contractors. These systems are designed for professional installation and typically include the components your installer will need.
Here’s how it works:
Hire a licensed HVAC technician in your area
Use platforms like Angi, Thumbtack, or a local HVAC directory to find reliable professionals
Confirm your installer is experienced with the system type you’re purchasing
Note:
Please be aware if you choose to install HVAC equipment yourself and don’t possess proper HVAC licensing, you will void the manufacturer’s factory warranty. If you are capable of a factory-compliant installation yourself, you will need a licensed HVAC contractor to sign off on your work, fully confirming factory-compliant workmanship.
Need help? Contact Our Experts