3.5 ton - best for spaces between 1700- 2100 sq ft depending on your home's insulation and your climate
SEER2 rating helps consumers compare energy efficiency when choosing a new air conditioner. Higher SEER2 ratings mean significant utility savings. The federal minimum is 14 SEER2 with ratings into the 20 SEER2 range. A 20 SEER2 uses half the energy of a 10 seer much like MPG ratings for vehicles.
If you have an indoor furnace, or air handler, along with an outdoor AC unit, this system will serve as a replacement for both.
Best for cold climates and if you already have a gas furnace or a gas fuel supply already available.
You'll need about 25-30 Btu's per sq. foot for warmer winter climates and about 35-50 Btu's per sq. foot for colder winter climates - highly dependent on construction type and insulation values.
Low NOx and Ultra-Low NOx refers to California (only) emission limits on nitrogen oxides released by gas furnaces and are determined by local EPA standards and will vary for each type of gas furnace.
Goodman 3.5 Ton 14 SEER2 AC & Gas Furnace System – Two Stage Variable-Speed, 80000 BTU Low NOx Gas Furnace, 80% AFUE, Upflow, R32
3.5 ton - best for spaces between 1700- 2100 sq ft depending on your home's insulation and your climate
SEER2 rating helps consumers compare energy efficiency when choosing a new air conditioner. Higher SEER2 ratings mean significant utility savings. The federal minimum is 14 SEER2 with ratings into the 20 SEER2 range. A 20 SEER2 uses half the energy of a 10 seer much like MPG ratings for vehicles.
If you have an indoor furnace, or air handler, along with an outdoor AC unit, this system will serve as a replacement for both.
Best for cold climates and if you already have a gas furnace or a gas fuel supply already available.
You'll need about 25-30 Btu's per sq. foot for warmer winter climates and about 35-50 Btu's per sq. foot for colder winter climates - highly dependent on construction type and insulation values.
Low NOx and Ultra-Low NOx refers to California (only) emission limits on nitrogen oxides released by gas furnaces and are determined by local EPA standards and will vary for each type of gas furnace.
Smart, Quiet Heating with the Goodman GRVT80 Gas Furnace
The Goodman GRVT80 is a high-performance, two-stage, variable-speed gas furnace designed to deliver consistent warmth and energy efficiency. With up to 80% AFUE (Annual Fuel Utilization Efficiency), this furnace ensures that most of your fuel is converted into usable heat—helping you save on energy bills while staying comfortable all winter long.
Advanced ComfortBridge™ Technology for Smarter Control
Equipped with ComfortBridge™ technology, the GRVT80 continuously monitors and adjusts performance for optimal comfort and efficiency. Its variable-speed ECM blower motor and two-speed draft blower provide quiet, even airflow throughout your home, while the SureStart® silicon nitride igniter and self-diagnostic control board ensure reliable operation and easy maintenance.
Durable, Flexible, and Backed by Warranty
Built with a heavy-duty aluminized-steel heat exchanger and a fully insulated steel cabinet, the GRVT80 is engineered for long-lasting performance and quiet operation. It supports multi-position installation (upflow or horizontal), making it ideal for a variety of home layouts. Enjoy peace of mind with a Lifetime Heat Exchanger Limited Warranty, 10-Year Parts Warranty, and 10-Year Unit Replacement Warranty (with registration).
Two-stage gas valve provides quiet, economical heating
Commissioning and diagnostics via on board Bluetooth with the CoolCloud™ phone and tablet application
Efficient and quiet variable-speed ECM circulator motor gently ramps up or down according to heating or cooling demand
SureStart® Silicon Nitride igniter designed for long igniter life
Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display
Low constant fan speed circulates air throughout the home
Quiet, two-speed induced draft blower
California Low NOx emissions-compliant models available
Can no longer be installed in California’s South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.
AHRI Certified; ETL Listed
Cabinet Features
Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish
Multi-position installation: upflow, horizontal left or right
Removable bottom for side- or bottom-return applications
Convenient left or right connection for gas/electric service
Cabinet air leakage ≤ 2%
Coil and furnace fit flush for most installations
Goodman CAPTA6030C3 Cased Coil – 5 Ton, 21" Cabinet
Heavy-duty cooling and heating performance
The Goodman CAPTA6030C3 provides 5 tons of capacity in a durable 21-inch cabinet. Designed with an all-aluminum coil and factory-installed TXV, it is optimized for long-term performance in larger homes.
This model is engineered for efficiency and durability, ensuring consistent comfort with Goodman systems.
ACDirect does not yet provide installation services directly. However, most of our customers successfully arrange installation through local licensed HVAC contractors. These systems are designed for professional installation and typically include the components your installer will need.
Here’s how it works:
Hire a licensed HVAC technician in your area
Use platforms like Angi, Thumbtack, or a local HVAC directory to find reliable professionals
Confirm your installer is experienced with the system type you’re purchasing
Note:
Please be aware if you choose to install HVAC equipment yourself and don’t possess proper HVAC licensing, you will void the manufacturer’s factory warranty. If you are capable of a factory-compliant installation yourself, you will need a licensed HVAC contractor to sign off on your work, fully confirming factory-compliant workmanship.
Need help? Contact Our Experts
(866)-862-8922
Hours:
Monday - Friday: 8am to 9pm EST Saturday: 8am to 8pm EST Sunday: 11am to 8pm EST